ASIR Purification system from Dynamic Extractions Standard Impurity isolation – Triphenylphospine oxide removal from crude reaction mixture

publication date: Sep 27, 2011
 | 
author/source: Dynamic Extractions
Download Print Send a summary of this page to someone via email.
Spectrum HPCCC instrumentIn medicinal chemistry a challenging aspect to preparing compounds for testing, as lead molecules, can be their isolation from the crude reaction mixture that may contain catalysts, salts, metals, and other components which interfere with traditional purification methods.   One such problematic compound is triphenylphosphine oxide (TPPO).  TPPO is notoriously difficult and time consuming to remove using standard solid phase chromatography methods. In this example a standard HPCCC method has been developed that targets TPPO, regardless of the compound of interest's polarity. This enables chemists to rapidly remove TPPO from crude reaction mixtures and isolate suitable quantities of high purity target compound(s).                                                                   

chromatogramThe chromatogram shows the method applied to a reaction workup of a Staudinger reduction of a protected glycosylazide.  In this particular example the target compound elutes after TPPO, as it is non-polar relative to TPPO. The TPPO elutes as a single symmetrical, narrow peak; no streaking or tailing occurs.  The method is designed so that TPPO will always elute at 31 minutes.  The desired target reaction products will elute earlier if more polar or later if more non-polar than TPPO.  Total recovery of applied reaction mixture is achievable using this system.

Dynamic Extractions now provides their SII purification system to solve these challenges. Incorporating our Spectrum HPCCC instrument, that is preprogrammed with a number of standard methods for impurity removal. Sample loading from a few milligrams to a gram is possible on this system. The scientist simply loads their sample, selects the impurity to be removed and the system will then deliver the purified material at the fraction collector. The system also incorporates pumps, detection, auto-sampler, fraction collector, valving and software.

For more information about this application contact Dynamic Extractions in either the UK (+44 (0)1753 696979) or the USA (+1 732 230 3060) or via our website at www.dynamicextractions.com



blog comments powered by Disqus



Can't find what you are looking for?

Company Name:

Location:

Product:



Please note Lab Bulletin does not sell, supply any of the products featured on this website. If you have a product enquiry, please contact the supplier directly.


Lab Bulletin is published by newleaf marketing communications ltd
Lab Bulletin 2012 Media information Pack